SAFETY PRECAUTIONS:

  1. Cleaning the unit, while it is plugged in may result in electric shock, electric spark and serious injury. Unplug the unit before cleaning or maintenance.
  2. Our air purifier is used 50 / 60Hz, 50Hz -60Hz.
  3. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.   These limits are designed to provide reasonable protection against harmful interference in a residential installation.   This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  4. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING: To reduce the risk of fire, electric shock or injury, read and understand this user guide before operation this appliance.

  1. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
  2. Do not operate unite if cord or plug is damaged. Doing so can result in electric shock. Discard the damaged unite or take if to an authorized service facility for examination and /or repair.
  3. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. DO NOT ROUTE CORD UNDER FURNITURE OR APPLIANCES. Arrange cord away from traffic area and where it will not be tripped over.
  4. Only use the air purifier as described in this manual.
  5. Do not handle the unit with wet hands. Thoroughly dry your hands before handling any part of the air purifier.
  6. Hair, loose clothing and body parts can get caught in the machine resulting in injury. Keep hair, loose clothing and body parts away from openings and moving parts.
  7. Do not unplug by pulling on the cord. Doing so may result in electrical spark or fire, Unplug the unit by grasping. And pulling the plug.
  8. Do not use an extension cord.
  9. Do not place the air purifier near sources of heat, such as: stove tops, ovens, radiators or computers.
  10. Unplug the appliance from the power supply before servicing.
  11. This equipment should be inspected frequently and the dirt that has collected should be removed regularly to prevent excessive accumulation that may result in flashover or fire.
  12. Do not use the air purifier outdoors or on wet surfaces.
  13. Do not use the air purifier in an enclosed space where flammable, combustible or explosive gases are present.
  14. Do not use in an area where toxic vapors, flammable dust or oxygen tanks are present. Checked the location and make sure these elements are not present.
  15. Do not place open flames, including candles, directly in front of the air purifier.
  16. It is important to keep all objects away from the air intake grille.

PRODUCT DIAGRAM:

Air Purifier Outlook

FEATURES AND OPERATION:

NEGATIVE IONS: Negative Ions abound in our natural environments such as forests, waterfalls, mountains and seaside. Negative ions are useful for enhancing the metabolism and homeostasis of the human body. This air purifier is equipped with a negative ion generator that can produce abundant negative ions by means of electric simulation.

MULTIPLE AIR PURIFICATION: 3 stages filter system: PP filter to collect big dust particles and to prolong the lifetime of HEPA; True 99.97% HEPA to filter the floating particles as small as 0.3 microns and pollen with little wind resistance; Efficient activated carbon filter to eliminate the strange odor, to filter the methanol and TVOC.

Filter

OPERATION ON CONTROL BOARD:

Before getting started, flip over the machine to reveal the filter cover.

Turn the filter cover counterclockwise to unlock position and remove the cover. Take out the filter and remove filter from its plastic packaging.

Reinstall the filter. Make sure the pull tabs are facing outward. Replace the filter cover.

POWER: When the plug is connected, the red power indicator light is lit, the atmosphere light is lit in blue then turn off. It means the machine is in standby mode. Touch POWER, the atmosphere blue light is lit and machine start working in middle speed, speed indicator light is lit in green. Re-touch POWER again, the machine is power off.

Power

ANION: Touch the ANION, the Anion indicator light is lit in green, the Anion start working. Re-touch ANION, the function stop working.

Long press ANION button for 2 seconds to turn on/off atmosphere light.

SPEED: The machine is working in middle speed after start working. When touch SPEED, it changes to high speed, speed indicator light is lit in blue. Touch again, it changes to low speed, speed indicator light is lit in yellow. Touch the third times, it changes to middle speed with green indicator light, and that cycle repeats.

FILTER CHANGE

When machine working hours sum to 3000, blue atmosphere light will start flashing slowly as reminding of filter replacement. After replacing the filter, re-plug the power cord and let the

machine in standby mode, touch the speed button for 3 times continuously and then long

press for 2 seconds, blue atmosphere light will be turned on after 5 seconds quick flashing. It means filter replacement has been done. Restart the machine, it will work normally.

How to replace filter:
  1. Turn off and unplug the machine.
  2. Flip over the machine to reveal the filter cover. Turn the filter cover counterclockwise to unlock position and remove the cover.
  3. Remove the old filter.
  4. Remove the new filter from its polybag and place it into the machine with the pull tabs facing the opening.
  5. Replace the filter cover onto the housing, make sure the arrows on the housing and filter cover align. Turn the filter cover clockwise to the lock position.
Filter replacement

WI-FI

  1. When first plugged in, all indicator lights on the control panel will turn on for 1 second and then turn off. The WIFI indicator light will continue to flash. When the WIFI has been connected, the indicator light will stay illuminated.
    • INSTALLING THE APP: The Comfort Zone app is compatible with both IOS and Android operating systems. Go to either the App Store or Google Play to download the app. Once installed on your phone, follow the in-app instructions to setup the app and link it to your device.
    • The 1-12hour timer function can be set using the App only. Note the 12 hour timer function is only accessible through the app. Once set, this function can be used to automatically turn off the device after a set amount of time.
    • The reset button in the App should only be used after the air purifier has been working for 3,000 hours.

TECHNICAL SPECIFICATIONS:

Input voltage: AC120V

Frequency: 50 / 60Hz, 50Hz -60Hz

Consumption power: 12W Negative ions: 3.0 million / cm³ Applicable area: 12m²

CADR: 59CFM (100m3/h)

Operating condition: Temperature: -10℃~55℃  Humidity: ≤95%RH