Overview
Robust Door Lock Body
KS & KC authentication give guaranted Quality and
insured Product Satisfaction.
Auto Lock/ Re Lock/Double Lock Function
User Friendly Function give Safety and easy usage.
Dummy Number Functions give high level safety.
Dummy Number & Real number combination give high level password.
Multi-level volume control / mute optional Function
User can easily select 7level Volumne Control.
Light Button indicate in the dark space
You can easy to use the device using light keypad buttons.
Emergency Power Function (9V square battery)
Emergency power working even if the batteries run out completely.
Anti high-voltage / anti fireproof / anti-hacking system
It is very safe for using anti high-voltage and anti-hacking system. Also
if the temperature is higher than certain temperature, the door will be
open automatically with warning sounds under the fire.
Safety Cautions
- Don’t install, repair or
disassemble the device
randomly. - This device is suitable
for home safety level,
other condition will
not be guarante quality - Please read operation
manual Carefully. - Don’t push or insert
the button with drill
or pin - Change the pin-number
regularly for the safety - Don’t heavy damage
on door lock - Do not insert the
batteries reversely.
it will be cause some
burst or leakage from
batteries . - Don’t put water into
the device. - When change battery,
please use all
new alkaline battery. - When you clean the
device, please use
the dry towel - Do not use any other
purpose for Door lock.
CONTENTS
Specification
Parts Name
How to use
Easy Function
(option)
Emergency Alarm
Function
Breakdown Cause and Solution
Consumer Protection Rules
Product Warranty
Setting Pin Number
Setting Smart Key
Setting BLE(Smartphone)
Delete setting Smartkey
Delete setting BLE
Open the gate(Keypad)
Lock the gate(Outside)
Open the gate(Inside)
Lock the gate(inside)
Force Lock Status
Autolock Setting
Manual Setting
Sound Pause Function
Volume Control Function
Dual Authentication &Registration on/off
Built in Remocon Setting
Heat Warning
Intruder Alarm
Warning Mischef and 1min stop function
Deadbolt(mortise) Error Alarm
Battery Replacement Warning
Emergency Power
Emergency Key(key type)
Product Standard
Division | Features | |
Install Condition | Normal Fire Door | Door thickness 40mm ~ 50mm |
Access Methods | Pin Number | 4~12 digit number combination(Up to 4 pin numbe |
Smart key | Up to 30 keys | |
Smarphone | Option | |
Remocon | Option | |
Rated Voltage | DC 6V | LR6 1.5V AA Size Alkaline Battery, 4 psc |
Emergency Power | DC 9V | Alkaline battery(Optional) |
Product Type | Fireproof type, Temperature sensor type, Key type, Master key door lock(D-NF-T-K- | |
Temperature Alarm | Temperature Sensor | 72 ±5 (Lab Conditions) |
62 ±5 (Normal Conditions) | ||
Material | External Enclosure | Al, Zn, ABS |
Internal Enclosure | Al, Zn, ABS |
RF Standard:
Item | Frequency | Channel | Modulation | Antenna power (field strength) |
RFID | 13.56Mhz | 1ch | ASK | Under 93.5dBuV/m@10m |
Wireless Devices | 447.275Mhz | 1ch | FSK | Under 10mW |
Features:
Parts Name
No | Name | Features |
Key Buttons | Register or change the pin number. Open the door with registered pin number. | |
Battery Alarm | Open/register the electronic key. | |
Smartkey Access Point | Smartkey access point for open gate. By Contracting smartkey open the door or register smart key. | |
Outside Handle | handle can open or close the doo.r | |
Emergency Power Supply Terminal | When battery fully discharged, contact 9V battery and power on emergency power working. |
No | Name | Features |
1 | Battery Cover | Cover for battery and buttons for registration of pin number & electronic key. |
2 | Link Pack | Receiver (CDL-447RM, option) |
3 | Register Button | Use registration or change the pin number or electronic key |
4 | Mortise | Lock or close the door for installing side of door. |
5 | Dead Bolts | Lock the door to door frame. |
6 | Wrench Bolts | Prevent to shake the door. |
7 | Sub Wrench Bolts | Check for Door open or Close. |
8 | Alkaline AA Battery | Battery for main power |
9 | Manual Lock Button | Lock the door under manual mode |
10 | Inner Handle | Open or close the door from inside. |
How to use
Caution: Please set the pin number while you
open the door.
- Open the inside [battery cover],push
the[Register]Button and hear “Beep”
sound shortly. - Check outside light on [Keypad]
push the button NO 1. - Set the pin number 4 to 12 digits.
- Push the [* ] button
make “Beep” Sound and succeed registration
One more push the [ *] button
and completed registration.
Setting Smart Key
- Newly registered smart key or re-registred, please register
at a same time. other card not possible except provided card. - Open the battery cover,
Push the registration button once
then you can hear “Beep” sound. - Check outside light on [Keypad]
push the 2 on the Keypad, direction Dimming - [Smart key]close up on [smart key input]
when succeed registration, sound beeping. - Push the [Register]button,
it completed Registration
Delete setting Smartkey
Open the inside [Battery cover]
push the[Register] Button
and hear “beep” sound shortly.
Check outside [Keypad] lightning on,
Push the Button, light on [# ]Button
Push the [# ]during 5sec.
it makes ‘Beep”sound and delete
entire smartkey information.
Open the gate (Keypad)
- Key pad openning
Touch [Keypad],
input [Password]. - Push the [* ]button and belling
beep sound Door will be released.
Open the gate (Smart Key)
- Smartkey Opening
BLE(smartphone)Opening (CDL – 3PBR Model type)
Registered [Smart Key]close to
[Smart key] access point. - Beep sound and open the Gate.
How to use
Auto Locking
Pull the inside handle
Closing the door and lock the door
after 2second automatically.
Manual Locking
Touch the [Keypad], door will be lock.
Emergency Alarm Function
- Heat Warning
When a fire is detected, a high temperature of about suspected (62Ⳅ ± 5Ⳅ), automatically releases the locked state with strong beeps for safety.
2. Heat Warning
Warning mischief and 1 minute stop function. Abnormally in the door is locked (For example: forcely open the gate) occurs when the door open condition is detected. Beep noise makes 80 db (db) beeper.
3. Warning mischief and 1 minute stop function
Abnormally in the door is locked
(For example: forcely open the gate) occurs when
the door open condition is detected
Beep noise makes 80 db (db) beeper.
If input not registered [password] or [Smart Key repeatedly entered
five times l stop operating 1 minutes with alarm.
4. Deadbolt (mortise)error alarm
Opened or locked, when the dead
bolt (square clamp) of the indoor
unit body is normally taken out, or
do not enter “beep, beep beep,
beep” warning sound occurs three
times.
5. Battery Replacement Warning
Battery icon light on the Keypad or make sound “bleek bleek
bleek”, please change battery. all battery change required.
CDL-3PBRBC Digital Door Lock User Manual COMMAX
https://fccid.io/CCECDL-3PBRBC/User-Manual/User-Manual-3371743
Break down cause and solution
Problem | Solution |
No Power | Please check battery status bad or gone power and check battery input direction please change new 4 alkaline Battery. |
No Change Password | Please input password short “Beep”sound one by one. Again password register / repeat input. |
No open the door though push the [ ]button | please check passwor input correctly When input password, keypad light off, it will be not change password , presss the [ ]button and check keypad light on, input password again. (if didnot input password within 7sec, it will be canceled.) |
Password / Smart key authentication success but no open the door | Please try 9V emergency power(square type) Lock can may broken. please contact installer. |
keep going alarm “Beleek x3 ” warning sound. | – Beep indicating the battery replaced. if you heard this alarm, please replace all new 4pcs battery. |
No enter Auto Locking | Please reset automode. Sound occurs the batteries discharge and does not work. please change all new battery |
Consumer Protection Rules
- COMMAX conducted a guarantee of the product as shown below each item, depending on the consumer compensation regulations.
- Please install the product can not be installed by a professional installer or authorized installer to install receive A / S if faulty.
Emergency Power
If the product fails within the first year after purchase (the warranty period), you get the free service only.
Consumer Damage Type | Compensation | ||
within Warranty | after warranty | ||
Functional defects in normal use occurred in 10 days | Product Exchange | ||
Functional defects in normal use occurred in 1month | Product Exchange | ||
Serviceable | same fail 3times again | Repair free | Repair charge |
same file 4times again | Product exchange | Repair charge | |
No Serviceable | When repair parts for repair but impossible (within the parts holding period)) | Product Exchange | Depreciation and exchange |
When repair parts are not impossible to repair (parts within the retention period) | Product Exchange | Depreciation and exchange |
Paid Service
1. For non-failure | If it is not subject to failure, it will be service charge. Please read the instruction manual.Installation issue on non-malfunction.Force damage on the device for lost password. |
2. If the consumer fails to negligence | User Handling of abuse or inappropriate repair, modification and trouble occurs.Non official installer or non professional person installed and make trouble.Drop or make damage by cause of fault or error. |
3. etc | If any trouble occurs due to natural disasters (lightning, fire, salt damage, flood, etc.)If the end-life of the consumable parts (batteries, etc.)normal case consumer receive within 15month(including distribution period) |
Product Warranty
Product Name | |
Product Number | |
Purchase (installed) Date | 20 year month days |
Customer’s Name | |
Telephone | |
Address |
Installer Company | |
Telephone | |
Address | |
Installer’s Name |
Please keep this document for full service must present this warranty.
- Warranty for this product is the warranty benefits to the contents listed in the warranty.
- The warranty period is calculated from the date of purchase, so please obtain a base purchase date.
FCC Statement
15.19:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
15.21:
Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment.
15.105(b):
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Disclaimers
The manufacturer, importer, and distributor shall not be liable for damages including accidental and personal injury due to the improper use or operation of this product. The information in this
user manual was written based on current product specifications. The manufacturer, iriver Limited, is adding new complementary features and will continue to apply new technologies in the future. Product specifications may be changed without prior notice.
iriver is not responsible for data loss due to product use.
Exposure statement
The transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.